Comprehensive Sampler for Atmospheric Flue Gas Particulates

Comprehensive Sampler for Atmospheric Flue Gas Particulates

  • Product Number:LD-2700S Series
  • Product Difference:Sampling of various toxic and harmful gases, total suspended particulates (TSP), inhalable particulates (PM10, PM2.5), and VOCs in ambient air and flue gas

Product Introduction

The Comprehensive Sampler for Atmospheric and Flue Gas Particulate Matter integrates dual-channel sampling for atmospheric gases, particulate matter (TSP, PM10, PM2.5), heavy metals, fluorides, dual-channel VOCs, dual-channel flue gas sampling, dual-channel flue gas VOC sampling, and constant temperature/constant flow functionality. It provides a comprehensive solution for sampling various toxic and harmful gases, total suspended particulates (TSP), inhalable particles (PM10, PM2.5), VOCs in environmental air and flue gas. This instrument features low power consumption, low noise, compact size, light weight, high load capacity, and superior sampling performance.

The instrument can be equipped with an optional GPRS wireless transmission module, enabling remote control via the internet and real-time monitoring of the instrument's operational status. After extensive long-term testing, the sampler meets the requirements for long-term, trouble-free operation even in harsh field environments.

ModelSpecifications
LD-2700S-11-channel particulate matter
LD-2700S-22-channel constant temperature/constant flow ambient air + 1-channel particulate matter
LD-2700S -32-channel constant temperature/flow VOC + 1-channel particulate matter
LD-2700S-42-channel constant temperature/flow flue gas + 1-channel particulate matter
LD-2700S-54-channel constant temperature/flow ambient air + 1-channel particulate matter
LD-2700S-64-channel constant temperature and flow ambient air + 1-channel high negative pressure particulate matter
LD-2700S-72-channel constant temperature and flow ambient air + 2-channel constant temperature and flow VOC + 1-channel particulate matter
LD-2700S-92 constant temperature and flow atmospheric channels + 2 constant temperature and flow VOC channels + 1 high negative pressure particulate matter channel
LD-2700S-114 constant temperature and flow flue gas channels + 1 high negative pressure particulate matter channel

Product Features

  • Low power consumption, minimal noise, lightweight, compact structure, simple and elegant appearance, and easy portability.

  • Dual-channel constant temperature and constant flow atmospheric sampling, dual-channel constant temperature and constant flow VOC sampling, single-channel particulate matter sampling, dual-channel constant temperature and constant flow flue gas sampling, and multiple environmental assessment solutions.

  • Atmospheric sampling utilizes an imported brushless diaphragm pump featuring low noise, high load capacity, stable flow rate, and an integrated molded orifice plate flowmeter.

  • VOC sampling achieves flow resolution down to 0.1mL/min. The orifice plate incorporates a built-in waterproof sensor, preventing corrosion damage from backflow of absorbent liquid and significantly reducing instrument failure rates.

  • Features heating and cooling functions with foam insulation to ensure constant-temperature sampling.

  • Particulate matter sampling utilizes an imported brushless fan for stable flow and strong load capacity.

  • Scheduled sampling allows independent control of each sampling channel, enabling sampling to start at any time within the day.

  • Power failure recovery: Continuously records sampling progress and automatically resumes sampling upon power restoration.

  • Storage and printing: Supports up to one million sample files. Optional Bluetooth printer available for printing stored files.

  • Flue gas sampling flow range: 0.1–1.5 L/min, meeting flow requirements for collecting various hazardous substances as specified in solution absorption methods.

  • Built-in imported high-performance sampling pump enables dual-path constant-temperature, constant-flow sampling for flue gas, ambient air, and VOCs, with independent control of flow rate and sampling duration.

  • Absorption bottles and desiccant cylinders feature integrated designs to fully ensure sample safety during sampling.

  • External rack accommodates sampling with various absorption bottles ranging from 10 to 125 ml.

  • Supports remote data transmission via Wi-Fi, 4G, or 5G.

Product parameters

Measurement Parameters

ItemParameter RangeResolutionDisplay Error
Dual-channel atmospheric sampling flow rate(0.1–1.0) L/min0.001 L/minBetter than ±2.5%
Dual-Channel VOC Sampling Flow Rate (Model A)(10–300) mL/min0.1 mL/min(10–100) mL/min better than ±5%
(100–300) mL/min Better than ±2.5%
Dual-Channel VOC Sampling Flow Rate (Model B)(10–600) mL/min0.001 L/min(10–200) mL/min better than ±5%
(200–600) mL/min Better than ±2.5%
Particulate Matter Sampling Flow Rate(10–130) L/min0.1 L/minBetter than ±2%
Pre-meter Temperature(-40 to 85) °C0.1 °CBetter than ±2 °C
Pre-measurement Pressure(-45 to 0) kPa0.01 kPaBetter than ±0.4 kPa
Ambient Temperature(-40 to 85) °C0.1 °CBetter than ±1 °C
Atmospheric Pressure(50–130) kPa0.01 kPaBetter than ±0.5 kPa
Atmospheric sampling temperature control(5–32) °C0.1 °CBetter than ±2 °C


Sampling Parameters

ItemParameter Range
Atmospheric Sampling Load Capacity0.2L/min0.5L/min0.8L/min1.0L/min
40kPa20kPa10kPa10kPa
Atmospheric VOC Sampling Load Capacity200mL/min(Model A)600mL/min(Model B)
6.5kPa
Particulate Matter Sampling Load Capacity16.7L/min50L/min100L/min
6kPa5.5kPa5kPa
Particulate Matter Sampling Load Capacity (High Negative Pressure)16.7L/min50L/min100L/min
20kPa20kPa17kPa
Sampling MethodManual Sampling: Starts sampling immediately after initiation
Automatic Sampling: Scheduled sampling throughout the day
Sampling DurationSingle Sampling Duration: 1 minute to 99 hours
Sampling Interval: 1 minute to 99 hours
Number of Samples: 1 to 99 times, single or cyclic sampling


Other Parameters

ItemParameter Range
DimensionsLength × Width × Height: 330 × 182 × 310 (mm)
Main Unit Weight<5kg (including lithium battery)
Power ConsumptionVOC Sampling < 20W; Atmospheric Sampling < 20W; Particulate Sampling < 30W; Temperature Control < 60W
NoiseVOC sampling < 50dB; Atmospheric sampling < 50dB; Particulate sampling < 54dB
StorageOne million sets
PrintingBluetooth micro printer (optional)
Power SupplyAC 220V ±22V, 50Hz or DC 12V
pagetop