Ambient Air Sampling Instrument

Ambient Air Sampling Instrument

  • Product Number:LD-H4
  • Product Difference:Particulate Matter Sampling Flow Rate (10–130) L/min, for capturing atmospheric particulate matter samples (TSP, PM10, PM2.5, etc.)

Product Introduction

Ambient Air Sampling Instruments (hereinafter referred to as samplers) are essential devices for capturing particulate matter (TSP, PM10, PM2.5, etc.) from the atmosphere. Developed through extensive consultation with experts and users, these samplers incorporate cutting-edge technologies in computing, sensors, and new materials, ensuring reliable quality, stable performance, and extended service life.

Environmental air sampling instruments employ the filter membrane weighing method to capture total suspended particulates (TSP) and inhalable particulates (PM10) or (PM2.5), fluorides, heavy metals, SVOCs, and other substances from the ambient atmosphere. They are suitable for routine and emergency monitoring of gaseous substances and aerosols by environmental protection, health, labor, safety supervision, military, scientific research, and educational departments.

Product Features

  • Features a 7.0-inch wide-temperature high-brightness color touchscreen display, offering clear visibility in sunlight, an aesthetically pleasing interface, and user-friendly operation.

  • Adjustable particulate sampling flow rate. Compatible with corresponding sampling heads for fluoride, heavy metals, SVOCs, and other substances.

  • Imported sampling pump with high load capacity, low noise, stable flow, and extended service life.

  • High-vacuum imported blower delivers over 20kPa load capacity at 100L/min.

  • Dual operation modes (button/touch) accommodate diverse user preferences.

  • Massive data storage capacity exceeding 100,000 sets.

  • Automatically measures temperature and atmospheric pressure, calculating standard-condition sampling volume.

  • Automatically protects data during power outages; resumes sampling upon power restoration.

  • Compact and lightweight for easy portability.

  • Aluminum alloy sampling head resists electrostatic adhesion.

  • Excellent dustproof and waterproof design ensures normal operation in rainy or snowy conditions.

  • Electromagnetic compatibility design provides strong resistance to interference and radiation.

  • Dual data output mode supports printing or USB export.

Product parameters

Key ParametersParameter RangeResolutionAccuracy
Particulate Matter Sampling Flow Rate(10-130) L/min0.001 L/minBetter than ±2.5%
Flow Stability

Better than ±2.0%
Flow Repeatability

Better than ±2.0%
Pre-meter Pressure(-35 to 35) kPa0.01 kPaBetter than ±2.5%
Atmospheric Pressure(50 to 110) kPa0.001 kPaBetter than ±500 Pa
Sampling Time1 min to 99 h 59 min1 minBetter than ±0.2%
Built-in Battery (Optional)29.4V 10.4AH
Equal Interval Sampling TimeAny setting within 99 hours 59 minutes
Number of equal-interval samples1 to 99 times
Noise< 60dB(A)
Dimensions & Weight165x330x275mm, Approx. 4.0kg
Power SupplyAC220V±10% 50Hz or DC29.4V/5A
Power Consumption< 100W
Sampling HeadPM2.5 Cutting CharacteristicsDa50=(2.5±0.2)μm & g=(1.2±0.1)μm
PM10 Cutting CharacteristicsDa50 = (10 ± 0.5) μm & g = (1.5 ± 0.1) μm
Inlet Velocity0.3 m/s
b/a0.625
Connection PortM20x1.5