Water Drop Angle Tester

Water Drop Angle Tester

  • Product Number:LD-JC2
  • Product Difference:Research-grade, fully automatic liquid delivery system, offering high cost-effectiveness, strong expandability, comprehensive functionality, and capable of meeting all routine measurement requirements

Product Introduction

The contact angle refers to the angle θ formed between the tangent line to the gas-liquid interface at the triple point of gas, liquid, and solid, and the solid-liquid boundary line on the liquid side. Contact angle measurement is currently the primary method for assessing surface properties.

The LD-JC2 Research-Grade Water Drop Angle Tester employs optical profilometry to measure sample surface properties including contact angle, wetting performance, surface tension, advancing/receding angles, and surface energy. Featuring a fully automated liquid dispensing system, this cost-effective instrument offers strong expandability and comprehensive functionality to meet diverse routine measurement needs. It is currently widely adopted in numerous universities, research institutes, and enterprises.

Water drop angle testers find extensive applications across diverse industries. In sectors such as mobile phone manufacturing, glass production, surface treatment, materials research, chemical engineering, semiconductor fabrication, coatings and inks, electronic circuits, textile fibers, and medical biotechnology, contact angle measurement has become an essential instrument for evaluating surface properties. (Certain testing functions require optional accessories.)
1. Wetting behavior of liquids on solid surfaces, including spreading, penetration, and absorption; static contact angle measurement via the sessile drop method;
2. Measurement of advancing angle, receding angle, contact angle hysteresis, rolling angle, and dynamic contact angle on solid surfaces;
3. Continuous real-time analysis and process recording of absorbing materials, including time-dependent contact angle curve analysis;
4. Contact angle measurement for various specialty materials such as powders, curved surfaces, and superhydrophobic/superhydrophilic samples;
5. Contact angle testing of materials immersed in liquids using the attached drop method;
6. Measurement of surface tension and its polar and dispersive components for various liquids using the free drop method;
7. Calculation of solid surface free energy and analysis of its polar and dispersive components;
8. Analysis of liquid adhesion work on solid surfaces to evaluate surface uniformity, cleanliness, and other properties.

The water contact angle tester primarily consists of five major components: light source, injection unit, sample stage, acquisition system, and analysis software. The device operates based on optical imaging principles.
① Light source employs a dense LED cold light design, ensuring uniform illumination, clear images, and extended lifespan;
② Injection unit utilizes a high-precision syringe pump for liquid delivery, controlled by software for quantitative and constant-speed dispensing, delivering stable droplets with accuracy up to 0.01 microliters;
③ The sample stage employs a three-dimensional manual precision adjustment platform, offering flexible operation and accurate positioning. The stage can be customized according to actual sample dimensions;
④ The acquisition system utilizes an imported monochrome CCD camera, ensuring stable shooting, clear images, and reliable results. The lens features German industrial-grade imported components with adjustable magnification from 0.5x to 5x, delivering distortion-free imaging;
⑤ The analysis software is highly functional, featuring one-click fully automated fitting capabilities and employing internationally advanced fitting methods to achieve precise fitting for various droplet morphologies;

Product Features

  • The host features a high-strength aerospace aluminum alloy structure combined with a modular design concept. It employs independently developed integrated chip circuit control and incorporates the design essence and configuration of internationally superior imported contact angle equipment, ensuring exceptional instrument stability.

  • It utilizes globally advanced contact angle analysis methods, enabling precise fitting for all types of droplet imaging. This includes Hengmei's proprietary differential ellipse and differential circle methods for specialized liquid imaging fitting.

  • An industrial-grade, densely adjustable LED cold light source system (lifespan exceeding 25,000 hours) ensures clearer imaging while preventing small droplet evaporation caused by excess heat.

  • As China's first provider of German-imported contact angle measurement calibration samples, we guarantee instrument precision. Angle calibration standards include 3°, 5°, 8°; 60°, 90°, 120°; and 115° (optional).

  • Features a high-performance Japanese-made industrial camera module and industrial-grade telecentric zoom lens, achieving near-zero image distortion for optimal imaging results.

  • Equipped with dual-side contact angle measurement and rapid fitting functionality, enabling comprehensive analysis of liquid-solid surface wetting properties and precise assessment of actual surface wetting conditions.

  • Features a USB 2.0 standard interface for fast data transfer, high compatibility, and stable imaging.

  • Includes forward/backward angle measurement for efficient evaluation of sample surface stability.

  • The flexible acquisition system design accommodates most measurement environments, easily handling complex sample surface measurements.

  • Dynamic capture and video-based rapid testing enable continuous recording of contact angle changes, followed by automated batch fitting via software.

  • Employing internationally advanced computational methods, the software achieves fully automated fitting to eliminate human-induced measurement errors.

  • Software automatically generates reports in multiple formats, including Word, Excel, and graphical spectrum formats.

  • Multiple optional accessories are available. Our robust R&D team can fulfill diverse custom measurement requirements proposed by clients.

Product parameters

Contact Angle Main Unit
Dimensions800mm (L) × 190mm (W) × 640mm (H)
Weight21KG
Power Supply220V / 60Hz
Light Source System
Light SourceDense LED adjustable blue-toned industrial-grade cold light source
LifespanService life exceeding 25,000 hours
Injection Unit
SyringeDedicated high-precision quartz syringe, 500μL capacity
Droplet VolumeSoftware-controlled automatic liquid delivery, precision up to 0.01μL
Injection Unit MovementVertical: 50mm; 50mm left-right travel
Acquisition System
CameraGenuine imported high-speed industrial-grade sensor, 300 frames/ S, maximum 2000W pixels
Lens0.5-5x telecentric zoom dual-adjustment microscope
Acquisition System Adjustment50mm front-back (3mm fine adjustment), adjustable viewing angle (level,俯视,仰视, 360° rotation for multi-angle observation)
Stage Assembly
Stage Dimensions160mm*200mm
Maximum Sample Size6 inches
Stage Movement

Manual front-back movement, Travel: 60mm, Accuracy: 0.1mm

Left/Right Movement Manual, Travel: 35mm, Accuracy: 0.1mm

Up/Down Movement Manual, Travel: 80mm, Accuracy: 0.1mm

Analysis Software
Contact Angle Measurement Range0-180°
Contact Angle Measurement Accuracy±0.1°
Interfacial Tension Measurement Range0-3000 mN/m
Interfacial Tension Measurement Accuracy0.01 mN/m
Analysis Methods

Domestically advanced contact angle measurement analysis software employs automatic fitting methods (one-click automatic fitting, eliminating manual error), including:

① Circle method fitting

② Ellipse/ Oblique Ellipse Fitting Method

③ Young-Laplace Fitting

④ Differential Circle/Differential Ellipse Method

Surface Free EnergyZisman, OWRK, WU, WU 2, Fowkes, Antonow, Berthelot, EOS, Adhesion Work, Wetting Work, Spreading Coefficient
Dynamic Contact Angle FittingBatch Screenshot Fitting, Continuous Video Automatic Fitting, Automatic Online Real-time Fitting
Table/ Interfacial Tension TestingPendant Drop Method (Supports Real-Time Fully Automated Dynamic Surface Tension Testing)
Testing Droplet StatesPendant Drop, Sessile Drop (2/3 States), Bubble Lift, Sessile Drop on Needle, Sessile Drop on Substrate