Fully Automatic Secondary Thermal Desorption Instrument

Fully Automatic Secondary Thermal Desorption Instrument

  • Product Number:LD-HA3
  • Product Difference:30 sample positions accommodate large sample volumes, analyze chemical composition, and evaluate thermal resistance

Product Introduction

The fully automated secondary thermal desorption instrument delivers outstanding performance in both operational capabilities and differential thermal analysis. It enables high-precision weight measurement with a broad monitoring range, capable of analyzing extremely small samples. Additionally, this instrument facilitates comparative analysis between samples and reference standards to obtain information on the chemical composition of samples. For thermal stability testing, it measures sample mass changes and weight loss rates relative to temperature variations, thereby evaluating the thermal resistance of samples.

Product Features

  • 10-inch color touchscreen with comprehensive, intuitive parameters for online monitoring.

  • Power-on self-test, gas pressure differential alerts, automatic positioning, and sample tray calibration.

  • Full load capacity of 30 sample positions to accommodate large sample volumes.

  • Program-controlled sample tray tube positions enable targeted tube detection.

  • Microcomputer program control allows method parameter settings with real-time animated display of operational status and runtime.

  • Four independently heated zones: desorption chamber, injection valve, sample transfer line, and secondary desorption chamber.

  • Fully automated low-temperature secondary desorption using semiconductor cooling.

  • All gas lines passivated.

  • Automatically executes primary desorption, secondary desorption, and backflush cleaning based on method parameters.

  • Synchronizes startup with GC and chromatographic data processing workstations for rapid analysis initiation.

Product parameters

Primary Desorption Temperature Adjustment RangeRoom temperature to 400°C, accuracy ±0.5°C, increment 1°C freely adjustable
Secondary Desorption Temperature Adjustment RangeRoom temperature to 400°C, accuracy ±0.5°C, increment 1°C freely adjustable, heating rate >60°C/min
Focused cold trap temperature adjustment range−35℃ to −5℃, accuracy ±0.5℃, increment 1℃ freely adjustable
Sample-related line temperature adjustment rangeRoom temperature to 240℃ (dependent on ambient temperature), accuracy ±1℃ Increment: 1°C, freely adjustable
Six-way valve temperature control rangeRoom temperature ~ 200°C, accuracy ±1°C Increment: 1°C, freely adjustable
Number of sample positions30 positions
Sample tube specificationsDiameter 1/4 inch, Length 3.5 inches
Analysis AccuracyRSD < 2.5% (Depends on GC performance and operating technique)
Dimensions/Net Weight550x450x540mm/Approx. 25KG