Gas Chromatograph for Methanol and Ethanol Detection in Baijiu

Gas Chromatograph for Methanol and Ethanol Detection in Baijiu

  • Product Number:LD-GC
  • Product Difference:Specialized for detecting methanol and ethanol residues, 10-inch touchscreen

Product Introduction

Gas Chromatograph for Methanol and Ethanol Detection in Baijiu Specifically designed to detect residual methanol and ethanol.

Product Features

  • 10-inch touchscreen display for intuitive operation.

  • Versatile applications with straightforward maintenance.

  • Pressure protection: Carrier gas pressure protection automatically shuts off power when pressure drops below 0.1 MPa, safeguarding column integrity.

  • Real-time display of temperatures and operating conditions for all channels enables online monitoring and precise data control.

  • FID features automatic ignition, eliminating the need for manual ignition.

  • Accurate temperature control with 10 temperature control channels.

Product parameters

Pressure Protection Method

The carrier gas system features pressure protection. When gas pressure drops below 0.1 MPa, the instrument automatically cuts off power to effectively safeguard column integrity and operational safety.

The FID incorporates automatic ignition functionality, eliminating the need for manual ignition.
Display Method10-inch touchscreen monitor
Temperature Control Zones10-channel temperature control
Temperature Control Accuracy±0.1℃ to ±0.2℃
Temperature Control RangeRoom temperature ±8℃ to 450℃, in 1℃ increments
Programmed Temperature Ramp16-step programmed ramp, ramp rate 0.1-40℃/min, in 0.1℃ increments, Start/stop time range: 0 - 6000 min, in 1 min increments
Maximum Temperature450℃
External Events8-channel external events, supports installation of solenoid valves, etc.
Power Supply220V 50Hz 2000W
Hydrogen Flame Ionization Detector (FID)Mass-type detector suitable for trace analysis of organic compounds
◎Ignition method: Automatic ignition
◎ Detection limit: Mt ≤ 5×10⁻¹¹ g/s (n-hexadecane-isooctane solution)
◎ Noise: ≤ ×10⁻¹⁴ A
◎ Drift: ≤ 1×10⁻¹³ A/30 min
◎Linear range: ≥10⁶
Thermal Conductivity Detector (TCD)Concentration-type detector, suitable for macro-level analysis of organic and inorganic gases
◎Sensitivity: S≥3500 mV•mL/mg (Standard) 5000 mV•mL/mg (High Sensitivity) (Benzene-Toluene Solution)
◎Noise: ≤0.01 mV
◎Baseline drift: ≤0.03 mV/30 min
◎Linear range: ≥10⁴
Electron Capture Detector (ECD)Radioactive ionization detector suitable for trace analysis of compounds containing heteroatoms such as N, O, and S
◎Radioisotope: ⁶³Ni Activity: 370 MBq (10 mCi)
◎Detection Limit: ≤1×10⁻¹⁴ g/s
◎Noise: ≤0.03 mV
◎Baseline drift: ≤0.2 mV/30 min
◎Linear range: ≥10³
Flame Photometric Detector (FPD)Mass-type detector suitable for trace analysis of sulfur- and phosphorus-containing compounds
◎ Detection limit: (S) ≤ 5×10⁻¹¹ g/s, (P) ≤ 1×10⁻¹² g/s
◎ Noise: ≤ 0.03 mV
◎Baseline drift: ≤0.2 mV/30 min
◎Linear range: ≥10³ (S), 10² (P)
Nitrogen-Phosphorus Detector (NPD)Mass-type detector suitable for trace analysis of nitrogen- and phosphorus-containing compounds
◎ Detection limit: (N) ≤ 5×10⁻¹² g/s, (P) ≤ 1×10⁻¹² g/s
◎ Noise: ≤0.03 mV
◎ Baseline drift: ≤0.2 mV/30 min
◎ Linear range: ≥10³ (N), 10² (P)