Portable Methane Gas Leak Detector

Portable Methane Gas Leak Detector

  • Product Number:LD-LYY100
  • Product Difference:100-meter Rifle

Product Introduction

The portable methane gas leak detector consists of two components—a transmitter and a receiver—both of which are integrated into a single probe. The probe emits a laser beam toward a distant surface, with the laser path directed above potential leak points; the receiver then captures the reflected signal for calculation and processing. The telemetry instrument is designed based on the TDLAS principle, which relies on the fact that methane molecules absorb light at specific wavelengths. If a methane gas plume is present in the optical path, the emitted laser is partially absorbed, and the receiver detects a reduction in the light signal proportional to the number of gas molecules in the path.

The telemetry instrument provides sensitive, rapid, and stable responses to the target gas in hazardous gas environments. The advanced open-system design ensures ease of use, and the built-in narrowband filter effectively prevents sunlight from interfering with the signal.

The telemetry instrument features a built-in range-switching mechanism that automatically adjusts the range based on the intensity of the received light.

Product Features

  • Fast Detection: Detection time is only 0.015 seconds.

  • Long-Range Detection: Detects methane and methane-containing gas leaks at distances up to 200 meters.

  • High Accuracy: Specific laser detection reacts only to methane gas and is not affected by environmental conditions.

  • High Safety Rating: Intrinsically safe explosion-proof design.

  • Easy to Use: Automatically detects upon startup; no periodic calibration required; virtually maintenance-free.

  • Features a built-in sensitivity adjustment mechanism, unaffected by the intensity of reflections from surfaces.

  • Touchscreen design for user-friendly operation with a simple interface.

  • The device features an integrated standard gas chamber that monitors the laser wavelength in real time to enable automatic calibration.

Product parameters

ParametersMinimumTypicalMaximumUnit
DimensionsLength 300 × Diameter 65mm
Main MaterialPC + ABS--
Surface FinishSatin--
Product Weight--650--g
General Specifications
Test Distance0.1100220m
Response Time--0.0150.03s
Detection Range0--99999ppm·m
Operating Temperature-20--50°C
Operating Pressure40--160kPa
Operating Humidity----98%RH
Sensitivity--2.5--ppm·m
Explosion-proof rating--Ex ib IIC T4 GB--
Protection Rating
IP68

Standby Time101213h
Alarm MethodsLCD alarm display, audible alarm
Aiming methodGreen laser pointer and sight (built-in power supply; no battery replacement required)
Power supply2 batteries, user-replaceable
Display1–2.4-inch high-brightness LCD display, supports switching between ppm·m, %LEL·m, and %VOL·m units
Basic error(0–1,000) ±50ppm·m
(1,000–50,000) ±10% of true value
Laser SafetyDetection Laser CLASS I--
Indicator Laser CLASS IIIR
Electrical Specifications
Operating Voltage6.57.28.4V
Power Consumption1.21.52.5W
Battery Capacity--8000--mAh