Animal disease diagnostic instruments are devices used to detect the presence of pathogens or diseases in animal bodily samples. They play a vital role in animal health monitoring, epidemic control, and prevention. There are numerous types of animal disease diagnostic instruments, with specific usage methods and technologies depending on the type of disease being tested for and the sample type being analyzed.
The animal disease diagnostic instrument developed by Shandong Laierde employs polymerase chain reaction (PCR), a widely used molecular biology technique for detecting pathogen DNA or RNA in animal fluids or tissue samples. PCR analyzers amplify and detect specific pathogen nucleic acid sequences to determine whether an animal is infected with a particular disease.
Utilizes PCR technology to ensure precise and reliable pathogen detection results.
Features high sensitivity, simple operation, and time-saving efficiency.
High-definition touchscreen operation requires no training for easy mastery.
Efficient report generation with automatic PDF report creation.
Basic Parameters | Dimensions | 235mm*385mm*175mm (W*D*H) |
Weight | 5.6kg | |
Electrical Specifications | ~220V/50Hz, 255W | |
Data Interface | USB 2.0 *2 (two on the right side) | |
Environmental Parameters | Operating Conditions | Temperature: 10-30℃, Humidity: 20%~80% |
Transportation & Storage Conditions | Temperature: -20~55℃, Humidity: 20%~80% | |
Altitude | < 2500 meters | |
Noise Level | A-weighted, < 60dB | |
Sample Parameters | Sample Capacity | 16 × 0.2mL |
Tube Type | Single tube, 8-well strip, 16-well tubes | |
Sample Volume | 15-100μL | |
Temperature Characteristics | Heating/Cooling Method | Semiconductor heating/ Cooling |
Temperature Range | 4°C-99°C | |
Maximum Heating Rate | ≥3.5°C/s | |
Average Heating Rate | ≥2.5°C/s | |
Maximum Cooling Rate | ≥3.5°C/s | |
Average Cooling Rate | ≥2.5°C/s | |
Temperature Control Accuracy | ≤±0.01℃ | |
Temperature Accuracy | ≤±0.1℃ | |
Temperature Uniformity | ≤±0.3℃ | |
Optical Characteristics | Number of Fluorescence Detection Channels | 2 channels |
Light-Emitting Device | High-brightness LED | |
Light-Collecting Device | High-sensitivity, High Signal-to-Noise Ratio Photodiode | |
Probe or Dye Compatibility | Single Channel | 470/520 FAM, SYBR Green |
Dual-channel | 530/570 HEX, JOE, VIC | |
Detection sensitivity | 1 copy | |
Linear detection range | 100~1010 copies | |
Coefficient of linearity | ≥0.999 | |
Channel crosstalk | No crosstalk | |
Detection repeatability | ≤1.0% |