The handheld mycotoxin detector is compact, lightweight, and small in size, making it easy to carry to various field environments for testing, such as emergency rooms, community clinics, and even remote areas. Compared to traditional large laboratory equipment, its portability significantly improves testing efficiency and flexibility.
Fluorescent immunoassay technology is a novel membrane-based detection technique based on antigen-antibody specific immune reactions. This technology uses strip-shaped fiber chromatographic materials with fixed detection lines (coated with antibodies or antigens) and control lines (anti-antibodies) as the stationary phase, with the test solution as the mobile phase. Fluorescently labeled antibodies or antigens are fixed to the connection pad, and the analyte moves along the chromatographic strip via capillary action.
For large-molecule antigens (proteins, viruses, pathogenic bacteria, etc.) with multiple antigenic determinants, the “sandwich” type double-antibody sandwich immunochromatography method is typically used. In this method, the analyte first binds to the fluorescently labeled antibody under the action of the mobile phase, and then binds to the coated antibody at the detection line to form a “sandwich” structure with the double-antibody sandwich.
Fluorescent immunoassay is applied in various fields such as medical diagnosis, tumor research, neuroscience research, drug development, food safety testing, and forensic identification.
① In drug development, handheld fungal toxin detectors can be used to screen and evaluate the efficacy and safety of drugs.
② In food safety testing, harmful substances such as additives and residues in food can be detected.
③ In forensic identification, it can be used to detect and analyze evidence in biological samples.
Portable and flexible, ready to test anytime: Compact and lightweight design, easy to carry to various on-site environments such as grain warehouses, processing plants, and markets, enabling mobile rapid testing.
Intelligent interaction, easy to operate: Equipped with an Android smart system and a 4.3-inch high-definition touchscreen, the interface is user-friendly and operation is smooth. No complex training is required to get started, significantly improving testing efficiency.
High-precision colloidal gold detection technology: Integrated colloidal gold module for mobile scanning, accurately detecting common mycotoxins such as aflatoxins and vomitoxins, with high sensitivity, strong specificity, and reliable results.
Data connectivity and efficient management: Supports WiFi wireless transmission, with detection data uploaded in real-time to the cloud or regulatory platforms, facilitating remote monitoring, data traceability, and statistical analysis.
Instant reporting and on-site output: Built-in high-speed thermal printer prints results immediately upon completion of testing, facilitating on-site record-keeping, archiving, or reporting, and improving work efficiency.
Durable and cost-effective: Integrated design reduces reliance on consumables, lowering long-term costs; robust chassis suitable for high-frequency use, meeting the demands of various harsh environments.
Screen | 4.3-inch touchscreen, resolution 800x480, internal storage 1+8GB |
Operating System | Android 4.4 |
Performance Standards | YY/T 1792-2021 Fluorescent Immunoassay Analyzer |
Detection Method | Reflective Photometric Detection |
Adaptor Card Holder | 70mm x 20mm |
Language | Chinese/ English |
Storage Capacity | 100,000+ |
Accuracy | Error Value ≤ 5% |
Stability | SW (Coefficient of Variation) ≤ 5% |
Repeatability | CV (Coefficient of Variation) ≤ 3% |
Resolution | 0.001 |
Detection Channel | Single Channel |
Detection Time | < 5 seconds |
Built-in Functions | Built-in quality control functions, with self-testing capabilities for both the device and test cards; Built-in card detection functionality, no test without a card |
Testing Method | Incubation testing, rapid testing (re-verification of test data) |
Testing Curve | Can verify the test results of the reagent card to prevent misjudgment |
Test Results | Reports test items, results of the tested substance, testing units, inspected units, inspector, testing time, detection limit, etc. can be displayed on the touchscreen and printed via the built-in printer |
Project Management | Supports expandable testing project functionality |
Interface Settings | Can modify headers and footer information to flexibly display instrument information |
Data Transmission | WiFi, Bluetooth, Type-C |
Data Processing | Data aggregation and upload to regulatory platforms via communication ports |
Temperature Range | Testing channel incubation and testing integrated, temperature range: room temperature +5°C to 60°C |
Printer | Thermal printer (thermal paper: 57×20 mm) |
Power supply | Input: AC 100V–240V/0.3A, 50Hz; Output: DC 5V/2A |
Battery capacity | 6000 mAh, with battery level display |
Operating environment | Temperature: 0°C to 50°C, Humidity 0–90% |
Dimensions and Weight | 206mm × 85mm × 60mm, 670g |